sciensano.be
Gepubliceerd op sciensano.be (https://www.sciensano.be)

Home > Biblio > Estimating the Reliability of Low-Abundant Signals and Limited Replicate Measurements through MS2 Peak Area in SWATH

Estimating the Reliability of Low-Abundant Signals and Limited Replicate Measurements through MS2 Peak Area in SWATH

[1]
Downloaden 429.64 KB [1]

Public Access

Published

Peer reviewed scientific article

Engels

DOI : https://doi.org/10.1002/pmic.201800186 [2]

Auteurs

Franck Limonier [3]

Trefwoorden

  1. MS2 peak area [4]
Article written during project(s) : 
PLPROT Gebruik van proteomica voor de kwaliteitscontrole van intraveneuze immunoglobulines [5]

Samenvatting:

Sequential windows acquisition of all theoretical fragment ions mass spectrometry (SWATH-MS) provides large-scale protein quantification with high accuracy and selectivity. Nevertheless, reliable quantification of low-abundant signals in complex samples remains challenging, as recently illustrated in a multicenter benchmark study of different label-free software tools. Here, the SWATH Replicates Analysis 2.0 template from Sciex is used to highlight that the relationship between the MS2 peak area and the variability can be described by a function. This functional relationship appears to be l…
Lees meer

Samenvatting

Sequential windows acquisition of all theoretical fragment ions mass spectrometry (SWATH-MS) provides large-scale protein quantification with high accuracy and selectivity. Nevertheless, reliable quantification of low-abundant signals in complex samples remains challenging, as recently illustrated in a multicenter benchmark study of different label-free software tools. Here, the SWATH Replicates Analysis 2.0 template from Sciex is used to highlight that the relationship between the MS2 peak area and the variability can be described by a function. This functional relationship appears to be largely insensitive to variation in samples or acquisition conditions, suggesting a device-intrinsic property. By using a power regression, it is shown that the MS2 peak area can be used to predict the quantification repeatability without relying on replicate injections, thus contributing to high-throughput confident quantification of low-abundant signals with SWATH-MS.

Associated health topics:


Source URL:https://www.sciensano.be/nl/biblio/estimating-reliability-low-abundant-signals-and-limited-replicate-measurements-through-ms2-peak-area

Links
[1] https://www.sciensano.be/sites/default/files/limonier_et_al-2018-proteomics.pdf [2] https://doi.org/10.1002/pmic.201800186 [3] https://www.sciensano.be/nl/people/franck-limonier/biblio [4] https://www.sciensano.be/nl/biblio?f%5Bkeyword%5D=35885&f%5Bsearch%5D=MS2%20peak%20area [5] https://www.sciensano.be/nl/projecten/gebruik-van-proteomica-voor-de-kwaliteitscontrole-van-intraveneuze-immunoglobulines