Did you mean
validated

Search results - 11 results

Papilloplex HR-HPV test has non-inferior clinical performance for detection of human papillomavirus infection: assessment using the VALGENT framework.

detection and separate identification of 14 hrHPV types. Here, we present the clinical validation of the test in SurePath samples in comparison to a clinically validated reference test, the GP5 +/6+Enzyme ...

Assessment of the clinical and analytical performance of the Aptima SARS-CoV-2 assay using the VALCOR protocol.

a study protocol designed to set up a framework for test validation of SARS-CoV-2 virus assays. Using clinical samples collated from VALCOR, the performance of Aptima SARS-CoV-2 assay was assessed against ...

Evaluation of the clinical performance of OncoPredict HPV® SCR assay within the VALGENT-2 framework.

cervical cancer screening should be clinically validated according to international criteria. OncoPredict HPV ® Screening (SCR) is a partial genotyping multiplex real-time PCR assay targeting E6 / E7 genes ...

Tackling cervical cancer in Europe amidst the COVID-19 pandemic.

powerful tools are available for primary and secondary prevention of cervical cancer, among which prophylactic HPV vaccines, and screening using validated HPV tests for women—including some tests that can be ...

Clinical and Analytical Evaluation of the Anyplex II HPV HR Detection Assay within the VALGENT-3 Framework.

Cervical Neoplasms Abstract: In 2012, VAL idation of human papillomavirus (HPV) GEN otyping T ests (VALGENT) was initiated to provide a formalized and uniform study framework for comparison and validation of ...

Validation of intra- and inter-laboratory reproducibility of the Xpert HPV assay according to the international guidelines for cervical cancer screening.

(hrHPV) types is more effective than cytology-based screening. This study completes the diagnostic accuracy assessment conducted previously within the framework of VALGENT-2 (Validation of HPV genotyping ...

VALHUDES: A protocol for validation of human papillomavirus assays and collection devices for HPV testing on self-samples and urine samples

C Cocuzza; F H Zhao; S Van Keer; A Vorsters Source: J Clin Virol, Volume 107 (2018) Keywords: cervical cancer diagnostic test accuracy SCREENING self-sampling Test validation Urine collection VALHUDES ...

Clinical Evaluation of INNO-LiPA HPV Genotyping II Assay Using the VALGENT Framework.

Neoplasms Abstract: In this diagnostic test validation study, we assessed the clinical accuracy and HPV genotyping performance of the INNO-LiPA HPV Genotyping II (INNO-LiPA) within the VALGENT-3 framework. ...

Clinical evaluation of a GP5+/6+-based luminex assay having full high-risk human papillomavirus genotyping capability and an internal control.

Oligonucleotide Probes Papillomaviridae Papillomavirus Infections Reference Standards Sensitivity and Specificity Young adult Abstract: The LMNX genotyping kit HPV GP (LMNX) is based on the clinically validated GP5 ...

IPAAC Rapport WP4: Cancer control policy interview survey

provision of structural budgets. Register-based collection of structured and validated data of lifestyles and interventions from electronic data sources in health care would be a key to evaluation and to ...

QR code

QR code for this page URL